Previous Page  6 / 16 Next Page
Information
Show Menu
Previous Page 6 / 16 Next Page
Page Background

Model TP5 C

with active cooling

Housing:

Signal inputs:

2 x analogue: 0/4–20 mA

8 x digital (flow, event, 1 inputs can be programmed freely)

Sampling method:

Suction height:

up to 8,5 m (at 1.013 hPa)

Pumping speed:

> 0,5 m/s at suction height up to 5 m (at 1.013 hPa)

Suction hose:

PVC, L = 5 m, ID = 10 mm

Sampling modes:

Time, flow, event-related and manual sample

Bottle variants:

1 x 10 L; 1 x 25 L, 2 x 13 L; 4 x 5 L; 16 x 1 L PE incl. freezer packs

24 x 1 L PE (standard version)

Overall dimensions:

1.028 x 550 x 468 mm (hxwxd)/Insulating box active

Weight:

approx. 40 kg; isobox with active cooling (24 x 1 L)

Ambient temperature:

0°–50° C

Sample temperature:

0°–40° C

Standards:

PE/PC (GF10)

Interface:

Signal outputs:

8 digital outputs, 1x of them as collective malfunction message

(max. hose length 20 m)

Vacuum 20–350 ml/Peristaltic pump 20–10.000 ml

Option: variable flow-proportional sampling

CE, sampling according to ISO 5667-10, EN 16479

Doublewalled, insulated lower part

MiniUSB, RS 232, optional: Ethernet RJ45, SDI-12

Thermostatic control:

compressor cooling (12 V/115 V/230 V)

Microprocessor control, foil keypad, back lit display

Option: LAN/GPRSUMTS/Web communication

(100 MB, 2 year ring memory FIFO at 1 min interval)

12 programs, userfriendly software

Control:

Power supply:

Sampler 12 V/

active box 230 V–50 Hz/115 V–60 Hz/12 V akku

10 Ah/charger 115 V oder 230 V

Innovation made in Germany

Technical data at a glance